Clyde Building
Inspections
★★★★★ 4.8 on Google · 570+ reviews

Slab pre-pour inspection in Clyde

The last time anyone can see the steel, the pods and the vapour barrier. After the truck arrives, every one of these items is permanent.

  • The day before the pour, while steel and pods are still open to view
  • About 1 hour on site
  • Report within 24 hours
Get your Clyde inspection priceTakes about a minute. No obligation.

Fully licensed & accredited

Stage2 of 7
When to bookThe day before the pour, while steel and pods are still open to view
Time on siteAbout 1 hour on site
Inspected againstAS 2870, AS 3600, NCC Part 3.2, the engineer's slab design and the soil report

What is included in a Clyde slab pre-pour inspection

  • Slab class and layout checked against the engineer's design and the soil report
  • Edge beam and internal beam depths and widths
  • Reinforcement size, spacing, laps and trench mesh
  • Bar chairs, cover and support so steel does not sit on the ground
  • Waffle pods, void formers and pod spacing
  • Vapour barrier coverage, laps and tape at penetrations
  • Plumbing and electrical penetrations and sleeves
  • Set-downs for wet areas, garage, porch and alfresco
  • Termite management components installed before the pour
  • Formwork alignment, level and set-out against the plans
  • Stormwater pipe cover and pit positions where visible
  • Site cut, fill and pier holes where visible
  • Hot water service and meter box slab extensions formed
  • Trench cleanliness and debris before the pour
Why it matters here

Slab pre-pour inspections on Clyde builds

Clyde slabs are mostly waffle raft on reactive ground, so bar chair spacing, concrete cover and the barrier under the slab decide how the house behaves in its first dry summer.

What we find at this stage in Clyde

  • Trench mesh inadequately supported at the edge
  • Slab mesh sagging between chairs
  • Reinforcement splices not tied
  • Beam width inconsistent with the drawing
  • Middle rib reinforcement not fully tied
  • Vapour barrier punctured and not patched
Reinforcement displaced within the internal beam, Clyde
Reinforcement displaced within the internal beam
Sample findings

Sample defects found during our slab pre-pour inspections in Clyde

Annotated findings from Slab pre-pour inspections on Clyde builds. Client addresses withheld.

Trench mesh inadequately supported at the slab edge, found during a slab pre-pour inspection in Clyde North
Trench mesh inadequately supported at the slab edge
Slab mesh sagging between bar chairs, reducing cover, found during a slab pre-pour inspection in Clyde North
Slab mesh sagging between bar chairs, reducing cover
Beam width inconsistent with the engineering drawing, found during a slab pre-pour inspection in Clyde North
Beam width inconsistent with the engineering drawing
Middle rib reinforcement not fully tied before the pour, found during a slab pre-pour inspection in Clyde North
Middle rib reinforcement not fully tied before the pour

The other stages of a Clyde build

  1. Bored piers inspection in Clyde1Bored piersAfter the holes are bored and steel cages are placed, before concrete
  2. Frame inspection in Clyde3FrameOnce the frame and roof trusses are up, before sarking and cladding
  3. Lock-up (pre-plaster) inspection in Clyde4Lock-up (pre-plaster)After cladding, roof and external doors, before plaster goes on
  4. Fixing inspection in Clyde5FixingOnce skirtings, architraves, doors and joinery are in, before painting
  5. Waterproofing inspection in Clyde6WaterproofingAfter the membrane is applied, before any tile is laid over it
  6. Pre-handover (PCI) inspection in Clyde7Pre-handover (PCI)Before you sign at practical completion, ideally a week ahead

All construction stage inspections in Clyde →

Guides

Construction stage guides for Clyde

All guides →

Book a slab pre-pour inspection in Clyde

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Slab pre-pour inspections in Clyde: common questions

How much notice do you need?

A day is usually enough, but tell us as soon as the pour is booked because these dates move.

What happens if we find something?

You send the report to the supervisor that afternoon. Most items are fixed before the truck arrives the next morning.

Do you check the plumbing under the slab?

We record penetrations and whether the barrier has been sealed around them. Testing the pipework is the plumber's certification, not ours.

Is the pour delayed?

That is between you and your builder. Most findings at this stage take an hour to fix.

What standard applies?

AS 2870 for residential slabs and footings, plus your engineer's drawing.

Can you inspect after the pour instead?

No. Nothing under concrete can be assessed once it is placed.

CallGet a Free Quote